Canyon Park Facility

All CKC test facilities are accredited to ISO Guide 17025 by A2LA. Click here for a listing of all CKC accreditations and agency listings.

Canyon Park Facility Capabilities

Commercial Testing

 

Emissions and Immunity

Emissions

Immunity

CANYON PARK CHAMBER 1
SITE C1

CANYON PARK CHAMBER 2
SITE C2

CANYON PARK CHAMBER 3 SITE CP-3

CANYON PARK BENCH 1
SITE B1

CANYON PARK BENCH 2
SITE B2

LAB DOOR DIMENSIONS

5’1”W X 7’9”H

5’10”W x 8’4”H

4’W x 7’H

6′ x 8′

DIAMETER OF TURNTABLE

8”

9’3”

9’

N/A

WEIGHT CAPACITY OF TURNTABLE

1.5 Tons

1.5 Tons

2 Tons

N/A

LAB DIMENSIONS

36’L x 16’Wx11’H

28’L x 16’W x 10’H

36’L x 20’W x 19.5’H

12’L x 12’W x 10’H

RAMP ACCESSIBLE

Yes

Yes

Yes

N/A

LOADING DOCK ACCESSIBLE

Yes

Yes

Yes

Yes

EUT SUPPORT, CABLE LENGTH NEEDED

18′

18′

15′

 

SITE CERTIFICATIONS

A2LA ISO 17025

A2LA ISO 17025

A2LA to ISO Guide 17025

A2LA ISO 17025

SPECIAL OPTIONS

Converts to MIL-STD Room. Emissions pre-testing

Converts to MIL-STD Room.  Emissions pre-testing

Water. Compressed Air.

OTHER

 Fully-Anechoic Room (FAR)

 Fully-Anechoic Room (FAR)

Full-Scan Height, 5m Emissions Chamber.

POWER CAPABILITIES

Single Phase
120Vac @ 60Hz; 20 Amp Max.
208Vac @ 60Hz; 30 Amp Max.
230Vac @ 50Hz; 15 Amp Max.

Three Phase
208Vac @ 60Hz; 30 Amp Max.

AC Power Supply
0-300Vac @ 45-5000Hz; 15 Amp Max.

DC Power Supply
0-100VDC; 2000 Watts Max.

Canyon Park Facility Capabilities

Military and Aerospace Testing

 

Immunity/Emissions

Support Room

Immunity/Emissions

Support Room

CANYON PARK MIL CHAMBER 1
SITE M1 (CP-M1)

CANYON PARK MIL CHAMBER 2
SITE M2 (CP-M2)

CANYON PARK MIL CHAMBER 3
SITE M3 (CP-M2)

CANYON PARK MIL CHAMBER 4
SITE M4(CP-M2)

LAB DOOR DIMENSIONS

6’ x 7’

3’ x 7 ’

3’ x 7 ’

3’ x 7 ’

TEST TABLE SIZE

21’8″L x 4’ W

2 ea. 8′ L x 3′ 6″ W
2 ea. 12′ L x 3′ 6″ W

2 ea. 11′ 8″ L x 4′ W

2 ea. 8′ L x 3′ 6″ W

LAB DIMENSIONS

17′ L x 24′ W x 10′ H

17′ L x 17′ W x 10′ H

17′ L x 14′ W x 10′ H

17′ L x 10′ W x 10′ H

RAMP ACCESSIBLE

Yes

Yes

Yes

Yes

LOADING DOCK ACCESSIBLE

Yes

Yes

Yes

Yes

EUT SUPPORT, CABLE LENGTH NEEDED

20′

20′

20′

20′

SITE CERTIFICATIONS

A2LA to ISO 17025

A2LA to ISO 17025

A2LA to ISO 17025

A2LA to ISO 17025

SPECIAL OPTIONS

Water, Compressed Air

Water, Compressed Air

Water, Compressed Air

Water, Compressed Air

OTHER

Semi-anechoic room. Radiated susceptibility 200 V/m up to 40 GHz. External generator power optional.

RF shielded room. External generator power optional

Semi-anechoic room. Radiated susceptibility 200 V/m up to 40 GHz. External generator power optional.

RF shielded room. External generator power optional

POWER CAPABILITIES

Single Phase
120V ac @ 60Hz; 20 Amp Max.
208Vac @ 60Hz; 30 Amp Max.
230Vac @ 50Hz; 15 Amp Max.

Three Phase
208Vac @ 60Hz; 30 Amp Max.

AC Power Supply
0-300Vac @ 45-5000Hz; 15 Amp Max.

DC Power Supply
0-100Vdc; 2000 Watts Max.