Mariposa Site A OATS (Open Area Test Site)

Commercial emissions testing for FCC, IC, CE mark, VCCI, CISPR, AS/NZS

ItemSpecificationComments
Range Length3, 10 and 30 meters 
Lab Door Size10′ wide x 10′ high 
Turntable Diameter40 ft.Flush-mounted
Turntable Weight Capacity46,000 lbs.Contact CKC prior for >10,000 lbs.
Cable length needed for isolation
of EUT support
Large Support:
70′ (radiated),
90′ (conducted)
Small Support:
10′ (under table)
 
Loading dock accessibleYes 
Ramp accessibleYes 
Water and compressed airYesNotify CKC prior to testing
Single phase power120VAC @ 60Hz; 200 Amp
208VAC @ 60Hz; 200 Amp
120VAC @ 50Hz, 200 Amp
230VAC @ 50Hz; 200 Amp
 
Three phase power208VAC @ 50 Hz, 100Amp
208VAC @ 60 Hz, 100Amp
480VAC @ 50 Hz, 100 Amp with generator rental
480VAC @ 60 Hz, 100 Amp with generator rental
 
Other